Copper Press Fit Fittings West London – Water & Gas In Stock

Copper Press Fittings Available From Stock – 15mm to 54mm (Water) & 15mm to 28mm (Gas)
Looking for copper press fit fittings in West London?
At Edwins Plumbing & Heating Supplies, we stock a wide range of water and gas press fittings, available for immediate collection.
From standard couplings to valves and irons, we carry everything you need on the shelf – no waiting, no delays.
Copper Press Fittings for Water Systems (15mm – 54mm)
We stock a full range of copper press fittings for water installations, suitable for domestic and commercial use.
Available sizes:
• 15mm
• 22mm
• 28mm
• 35mm
• 42mm
• 54mm
Available fittings:
• Elbows (90° and 45°)
• Tees
• Couplings
• Male & female irons
• Straight and bent isolation valves
• Lever valves

Press Fit Elbow

Press Fit Coupling

Press Fit Lever Valve

Press Fit Elbow
1/15
All available from stock for same-day collection in West London.
Copper Press Fittings for Gas (15mm – 28mm) – In Stock

Press Fit Gas Reducer

Press Fit Tee

Press Fit Gas Tee

Press Fit Gas Reducer
1/12
We also stock a strong range of gas-rated copper press fittings, ideal for safe and efficient gas installations.
Available sizes:
• 15mm
• 22mm
• 28mm
All fittings are ready on the shelf, so you can get what you need without delays.
Why Choose Edwins for Copper Press Fittings in West London?
• ✔ Large stock available immediately
• ✔ Water & gas press fittings in one place
• ✔ Trade & public welcome
• ✔ Expert advice at the counter
• ✔ No waiting – collect same day
More Plumbing Supplies Available at Edwins
• 👉 Plumbing Supplies West London
• 👉 Plumbing Consumables
• 👉 Boiler Spares
• 👉 Tap & Shower Spares
Need Copper Press Fittings Today?
Visit our trade counter in West London or give us a call.
We stock a wide range of copper press fittings for both water and gas systems – ready when you need them.
We supply copper press fit fittings across West London including Hammersmith, Acton, Ealing, White City and Shepherd’s Bush.
Copper Press Fittings – Regulations & When Or Where to Use Them
Copper press fittings are widely used across the UK and are fully compliant when installed correctly and used with approved systems
Unlike traditional solder ring systems, press fittings require no flame or soldering during installation, making them ideal for refurbishment work, commercial projects and faster installations.
For a more detailed comparison between both systems, read our guide:
Press Fittings vs Solder Ring — Which System Is Better?
They must:
• Be installed using the correct press tool and jaws
• Follow manufacturer instructions
• Be used within their pressure and temperature ratings
Copper press systems are commonly used in:
• Domestic plumbing
• Commercial installations
• Heating systems
• Gas installations (when using gas-rated fittings)

Water Installations – Regulations
For water systems, copper press fittings must comply with:
• Water Supply (Water Fittings) Regulations 1999
• WRAS approval (where applicable)
They are suitable for:
• Hot and cold water
• Heating systems
• Potable water (if approved)
👉 Press fittings are often preferred because:
• No soldering required
• Faster installation
• Reduced fire risk
Gas Installations – Regulations (IMPORTANT)
Gas press fittings must meet strict UK safety requirements.
Installations must comply with:
• Gas Safety (Installation and Use) Regulations 1998
👉 Key points:
• Only gas-approved press fittings can be used
• Installation must be carried out by a Gas Safe Register engineer
• Correct press tools and procedures must be followed
• Systems must be tested after installation
⚠️ Gas press fittings are NOT the same as water press fittings —
always use the correct type.
When And Why Should You Use Press Fittings?
Copper press fittings are ideal when:
• 🔥 Working in areas where soldering is not safe (e.g. near flammable materials)
• ⏱ Speed is important — significantly faster than traditional soldering
• 🏢 Commercial or large-scale installations
• 🔧 Retrofit work where draining systems fully is difficult
When NOT to Use Press Fittings
Press fittings may not be suitable if:
• You don’t have access to the correct pressing tool
• The system requires a different jointing method
• Manufacturer guidelines are not followed
Not sure which press fitting you need? Bring your parts into our West London counter and we’ll help you match it.