Thorough cleaner for systems older than six months.

Sentinel X400 High Performance Cleaner is specifically designed for cleaning older central heating systems. It is a non-acid treatment which restores circulation to radiators and pipework. Its ruthlessly efficient formula shifts built-up magnetite sludge, eliminating cold spots in radiators and restoring proper heat distribution.

Key featuresRestores systems suffering with circulation problems.Eliminates radiator cold spots.Prepares older systems for the installation of new components.Has a non-acid formula which does not cause pin-holing or leaks.Can be used in all types of indirect heating systems, including those containing aluminium.

Description
Sentinel X400 High Performance Cleaner restores a more even heat distribution to the house, keeping the property warmer and bills lower. Reviving an old heating system is a more cost-effective way to return warmth to a property than the installation of a whole new system.

Cleaning an old system before installing a new component also prolongs the effective life of the new component, whether a radiator or a boiler, reducing maintenance and replacement costs. Best practice, derived from documentation such as the UK Building Regulations Part L Domestic Heating Compliance Guide, is that a central heating system should be thoroughly cleaned and flushed out before the installation of a new boiler. We advise that systems should be cleaned in accordance with BS 7593.

Usage
To clean an older system in accordance with BS 7593, this product should be circulated (preferably at normal operating temperature, with all valves open and the pump turned to maximum flow) for a minimum period of 2 hours or until satisfactory performance is restored. Use in conjunction with a powerflushing device to achieve a more rapid clean.

Where systems are badly fouled, we recommend a longer circulation period (approximately 3-4 weeks). The product is not aggressive and can be safely left in the system for extended periods.

This product will not clear a completely blocked pipe.

Open Systems: Dose liquid via F&E cistern, via a by-pass feeder or use a Sentinel Dosing Vessel.

For details of how to dose using the Rapid-Dose format of this product, please watch the Rapid-Dose video.

When using concentrate gel, add directly to the heating system either via a radiator air bleed valve, or via the fill loop using the appropriate adaptor and a suitable caulk gun.

Sealed Systems: If the system is empty, add to any convenient point before filling. If full, use a Sentinel Dosing Vessel to inject via the filling loop or other access point.

For details of how to dose using the Rapid-Dose format of this product, please watch the Rapid-Dose video.

When using concentrate gel, add directly to the heating system either via a radiator air bleed valve, or via the fill loop using the appropriate adaptor and a suitable caulk gun.

Sentinel X400 Cleaner

SKU: X400
  •  I'm not sure which of Sentinel's cleaners is appropriate for the situation at hand

     

    About the problem

    You’ve arrived at your client’s property and some quick checks have made it evident that their central heating system is in need of a clean. Perhaps you have identified radiator cold spots and boiler noise, a jammed valve or a noisy pump. You have explained to your customer the benefits of central heating cleaning, these including improved performance, increased energy savings, and lengthened system life.

     

    Legislation and best practices recognise that in order to effectively clean a system, a chemical cleanser ought to be used, but it is important to ensure that you choose a suitable cleaner and don’t simply pluck one off the shelf at your local merchant. To achieve the best results for the system and for your customer, and to minimise callbacks, a little light research is necessary.

     

    The kind of debris and the amount of it will depend on the type of system, its age, and how well it has been maintained previously.

     

    The solution

    The system I'm dealing with is new

    In this scenario, your customer may struggle to understand how the system could possibly need cleaning. New systems can easily succumb to debris during and after installation as a result of carelessness in the manufacture and installation processes. 

     

    A few examples of the kind of debris that can be found in new systems include copper swarf, flux residues, casting sands and rust. Other contaminants can include greases and stamping oils used in the manufacturing process, sometimes applied excessively. When introduced into a central heating system, these materials can cause problems such as corrosion.

     

    So why X300 Cleaner for New Systems?

     

    X300 Cleaner for New Systems is designed to target excess flux residues, greases, and oils in addition to installation debris and sludge. Not only this, but X300 passivates the metal surfaces and helps to prevent copper deposition, a common cause of pinhole corrosion in radiators. Ideally, the product should be added at the first filling of the system. The water should then be circulated at normal operating temperatures for 2 hours before being flushed out. If you are using cold water, leave to circulate for 24 hours. Powerflushing is not necessary when using this product.

     

    The system I’m dealing with is not new, but is less than 6 months old

     

    If a system has not been cleaned prior to use, all of the aforementioned issues for new systems will be present, with the installation debris causing issues and damage to the system.

     

    So why X300 Cleaner for New Systems for systems less than 6 months old?

     

    As for new systems, X300 Cleaner for New Systems is designed to target installation and manufacture debris and contaminants. Once cleaned, it will passivate the metal surfaces and prevent copper deposition.

     

    In this scenario, the system may benefit from a manual flush using with X300.

     

    The system I’m dealing with is older than 6 months

    With older systems, the specific problem which you are trying to address will dictate what cleaning chemical will yield the results you desire.

     

    Why X400 High Performance Cleaner for older systems?

     

    If you are tackling circulation problems, identifiable as cold spots in radiators, most often caused by sludge build-up. The formation of this sludge is almost impossible to completely prevent and it often settles in low flow areas of the system.

     

    X400 High Performance Cleaner is the best central heating cleaner for this job as it breaks up, lifts and suspends this sludge, then allowing it to be flushed out of the system. In order to do this, it should be circulated, ideally at normal operating temperature, with all valves open and the pump set to maximum flow for a minimum period of 2 hours or until satisfactory performance is restored. In badly fouled systems, a period of circulation of approximately 3-4 weeks is recommended. This product can be used in conjunction with a powerflushing machine such as the Sentinel JetFlush 4 to improve cleaning effectiveness and shorten cleaning time.

     

    Why X800 Fast Acting Cleaner for older systems?

     

    Sometimes a more general clean is required, aimed at removing iron oxide and limescale deposits from pipework, heat exchangers and radiators. X800 Fast Acting Cleaner is ideal for these purposes, designed for use in conjunction with powerflushing equipment, but also proving a highly effective cleaner when manually flushed, too. It is effective both hot and cold.

     

    When might I need deposit remover?

    If the deposits you are dealing with are proving to be particularly stubborn, not remedied by the application of the aforementioned cleaners, a more potent product may provide the solution. Sentinel Deposit Remover is a mildly acidic formula designed to dissolve obstinate magnetite and scale deposits.

Need help finding the right part?

 At Edwins Plumbing & Heating Supplies, we specialise in plumbing supplies in West London, offering a wide range of tap spares, shower cartridges, boiler spares, fittings, and consumables for both trade and public customers.
 
If you’re unsure what you need, explore our main categories below or visit our Plumbing Supplies West London page for expert guidance and full product ranges:
 
👉 Boiler Spares & Parts
👉 Tap & Shower Spares
👉 We Can Identify Your Tap Or Shower Cartridge

👉 Plumbing Fittings
👉 Consumables

👉 Plumbing Supplies West London
👉 Soil, Waste, Push Fit

 
All products are available for fast collection or local delivery across West London, including Hammersmith, Acton, Ealing, White City, and surrounding areas.

bottom of page